Hi,
An in important aspect in the future developement of BIOSIG is the
encoding of events, markers and annotations.
The approach within BIOSIG, is a ono-to-one code-table according to
biosig/t200/eventcodes.txt. The events are grouped into several
problem-specific classes. All events are encoded in 16bit integer
numbers, the highest bit encodes On- and Offset. The latest version of
the table of eventcodes is available at:
http://cvs.sourceforge.net/viewcvs.py/biosig/biosig/t200/eventcodes.txt?view=markup
The table is prepared for extension to other application areas, as well.
Therefore, I'm asking you for suggestions on the extension of the table.
The event encoding is also supported by the powerful viewing and scoring
software SVIEWER which is part of BIOSIG. SVIEWER has all the standard
features of a viewer (e.g. scrolling, scaling, etc). Additionally, event
and marker information can be edited.
Best regards,
Alois Schloegl